Robin Svedlind and Filip Sandberg
Camfil Laboratories – Tech Center
Objective
To evaluate the particulate and molecular efficiency of the NV1050 in a test chamber using DEHS and Toluene.
Methodology
Test method: CADR
The aerosol and toluene were generated in the laskin nozzle and injected into a room until a pre-set concentration was achieved then the air cleaner was turned on. The results were then compared to the normal reduction of particles over time in the test chamber.
Summary of Results
The NV1050 reached a minimum efficiency with a 55% DEHS particle reduction on the low speed and a maximum efficiency with an 89% DEHS particle reduction on the high speed.
In the toluene declination test, the NV1050 removed 90% of the toluene within 6 minutes on the high speed and 90% after 17 minutes on the low speed.